HL7 v2.5.1 Specificationsv2.5.1

to moveEnter to openTry PID-5, ADT, 0004

BLC segment

The BLC segment contains data necessary to communicate patient abstract blood information used for billing and reimbursement purposes. This segment is repeating to report blood product codes and the associated blood units. SEQ LEN DT OPT RP/# TBL# ITEM# ELEMENT NAME 1 250 CE O 0426 01528 Blood Product Code 2 267 CQ O 01529 Blood Amount

The shape of one line

segmentBLC|BLC-1Blood Product Code|BLC-2Blood Amount

optional

Count the pipes to find a field, and count the empty ones too: an empty field still holds its place. Leave out the separator before BLC-2 and its value arrives as BLC-1, so the receiver stores Blood Amount as Blood Product Code.

This page carries the BLC field table as published and nothing beyond it. The field notes, vendor behaviour, FHIR mapping and parsing guidance that thePID page has are still to be written for BLC.

Every field

SEQLENDTOPTRP/#TBL#ITEM#Element nameCardinality
250CEO042601528Blood Product Code0..1

BLC-1 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
267CQO01529Blood Amount0..1

BLC-2 is a CQ, which holds 2 components separated by carets.

SEQLENDTOPTTBL#Component name
CQ.116NMOQuantity
CQ.2483CEOUnits

Message types carrying BLC

BLC appears in 1 message structure, belonging to 1 message type.