HL7 v2.5.1 Specificationsv2.5.1

to moveEnter to openTry PID-5, ADT, 0004

OM4 segment

The Technical Steward for the OM4 segment is ORDERS. This segment applies to observations/batteries that require a specimen for their performance. When an observation or battery requires multiple specimens for their performance (e.g., creatinine clearance requires a 24-hour urine specimen and a serum specimen), multiple segments may be included, one for each specimen type.

The shape of one line

segmentOM4|OM4-1Sequence Number -…|OM4-2Derived Specimen|OM4-3Container Description|OM4-4Container Volume|OM4-5Container Units|OM4-6Specimen|OM4-7Additive|OM4-8Preparation|OM4-9Special Handling…|OM4-10Normal Collection Volume| …4 more

optional

Count the pipes to find a field, and count the empty ones too: an empty field still holds its place. Leave out the separator before OM4-2 and its value arrives as OM4-1, so the receiver stores Derived Specimen as Sequence Number - Test/Observation Master File.

This page carries the OM4 field table as published and nothing beyond it. The field notes, vendor behaviour, FHIR mapping and parsing guidance that thePID page has are still to be written for OM4.

Every field

SEQLENDTOPTRP/#TBL#ITEM#Element nameCardinality
OM4-14NMO00586Sequence Number - Test/Observation Master File0..1
OM4-21IDO017000642Derived Specimen0..1
OM4-360TXO00643Container Description0..1
OM4-420NMO00644Container Volume0..1
250CEO999900645Container Units0..1

OM4-5 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
250CEO999900646Specimen0..1

OM4-6 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
250CWEO037100647Additive0..1

OM4-7 is a CWE, which holds 9 components separated by carets.

SEQLENDTOPTTBL#Component name
CWE.120STOIdentifier
CWE.2199STOText
CWE.320IDO0396Name of Coding System
CWE.420STOAlternate Identifier
CWE.5199STOAlternate Text
CWE.620IDO0396Name of Alternate Coding System
CWE.710STCCoding System Version ID
CWE.810STOAlternate Coding System Version ID
CWE.9199STOOriginal Text
OM4-810240TXO00648Preparation0..1
OM4-910240TXO00649Special Handling Requirements0..1
20CQO00650Normal Collection Volume0..1

OM4-10 is a CQ, which holds 2 components separated by carets.

SEQLENDTOPTTBL#Component name
CQ.116NMOQuantity
CQ.2483CEOUnits
20CQO00651Minimum Collection Volume0..1

OM4-11 is a CQ, which holds 2 components separated by carets.

SEQLENDTOPTTBL#Component name
CQ.116NMOQuantity
CQ.2483CEOUnits
OM4-1210240TXO00652Specimen Requirements0..1
OM4-131IDOY002700653Specimen Priorities0..*
20CQO00654Specimen Retention Time0..1

OM4-14 is a CQ, which holds 2 components separated by carets.

SEQLENDTOPTTBL#Component name
CQ.116NMOQuantity
CQ.2483CEOUnits

Message types carrying OM4

OM4 appears in 3 message structures, belonging to 1 message type.