HL7 v2.5.1 Specificationsv2.5.1

to moveEnter to openTry PID-5, ADT, 0004

RXC segment

If the drug or treatment ordered with the RXO segment is a compound drug OR an IV solution, AND there is not a coded value for OBR-4-universal service ID, which specifies the components (base and all additives), then the components (the base and additives) are specified by two or more RXC segments. The policy of the pharmacy or treatment application on substitutions at the RXC level is identical to that for the RXO level.

The shape of one line

segmentRXC|RXC-1RX Component Type|RXC-2Component Code|RXC-3Component Amount|RXC-4Component Units|RXC-5Component Strength|RXC-6Component Strength Units|RXC-7Supplementary Code|RXC-8Component Drug Strength Volume|RXC-9Component Drug Strength Volume…

required optional

Count the pipes to find a field, and count the empty ones too: an empty field still holds its place. Leave out the separator before RXC-2 and its value arrives as RXC-1, so the receiver stores Component Code as RX Component Type.

This page carries the RXC field table as published and nothing beyond it. The field notes, vendor behaviour, FHIR mapping and parsing guidance that thePID page has are still to be written for RXC.

Every field

SEQLENDTOPTRP/#TBL#ITEM#Element nameCardinality
RXC-11IDR016600313RX Component Type1..1
250CER00314Component Code1..1

RXC-2 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
RXC-320NMR00315Component Amount1..1
250CER00316Component Units1..1

RXC-4 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
RXC-520NMO01124Component Strength0..1
250CEO01125Component Strength Units0..1

RXC-6 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
250CEOY01476Supplementary Code0..*

RXC-7 is a CE, which holds 6 components separated by carets.

SEQLENDTOPTTBL#Component name
CE.120STOIdentifier
CE.2199STOText
CE.320IDO0396Name of Coding System
CE.420STOAlternate Identifier
CE.5199STOAlternate Text
CE.620IDO0396Name of Alternate Coding System
RXC-85NMO01671Component Drug Strength Volume0..1
250CWEO01672Component Drug Strength Volume Units0..1

RXC-9 is a CWE, which holds 9 components separated by carets.

SEQLENDTOPTTBL#Component name
CWE.120STOIdentifier
CWE.2199STOText
CWE.320IDO0396Name of Coding System
CWE.420STOAlternate Identifier
CWE.5199STOAlternate Text
CWE.620IDO0396Name of Alternate Coding System
CWE.710STCCoding System Version ID
CWE.810STOAlternate Coding System Version ID
CWE.9199STOOriginal Text

Message types carrying RXC